RP3350 ATX 300 Watts Redundant Power Supply

Features:
Input Characteristics:
1. INPUT VOLTAGE: THIS POWER SUPPLY HAS BOTH "AUTO AND MANUAL VOLTAGE SELECT SWITCH")
|
PARAMETER |
MIN. |
NOMINAL |
MAX. |
UNIT |
|
RANGE 1 |
90 |
115 |
132 |
VAC |
|
RANGE 2 |
180 |
230 |
260 |
VAC |
| *** THE INPUT FREQUENCY WILL BE: | 50 +/- 3HZ FOR 230V VERSION. |
| 60 +/- 3HZ FOR 115V VERSION. |
2. AC INPUT CURRENT :
|
PARAMETER |
MAX. (DUAL) |
MAX. (SINGLE) |
CONDITION |
|
RANGE 1 |
3.0 AMPS | 6.0A | AT 90 VAC |
|
RANGE 2 |
1.5 A | 3.0 A | AT 180 VAC |
3. INRUSH CURRENT (COLD START) :
|
PARAMETER |
MAX. |
CONDITION |
|
RANGE 1 |
40 AMPS | AT 115 VAC |
|
RANGE 2 |
80 AMPS | AT 230 VAC |
|
OUTPUT DC VOLTAGE |
REGULATION TOLERANCE |
OUTPUT DC CURRENT |
RIPPLE |
|
|
MIN. |
MAX. |
|||
|
+ 5V |
+ 5% - 6% |
7A |
25A |
80 mV |
|
- 5V |
+ 14% - 10% |
0A |
0.5A |
150 mV |
|
+ 12V |
+ 6% - 6% |
2.5A |
14A |
120 Mv |
|
- 12v |
+ 15% - 10% |
0.0A |
0.5A |
150 mV |
|
+3.3V |
+ 5% - 5% |
0.5A |
20A |
60 mV |
|
+5VSB |
+ 5% - 5% |
0A |
800mA |
50 mV |
* +5V AND 3.3V TOTAL MAXIMUM 125W.
General Information:
| Hold Up Time: | 16ms Minimum at full load & normal input voltage. |
| Dielectric Withstand: | Input/Output 1500 VAC for 1 second Input to frame ground 1500 VAC for 1 second |
| Humidity: | 10-90% RH |
| Efficiency: | 70% typical at full load |
| Power Good Signal: | On Delay 100ms to 500ms, Off Delay 1ms |
| Overload Protection: | +5V->5.5V-6.5V |
| Overload Current Protection: | Short Circuit |
| EMI Noise Filter: | FCC Class B |
| Operating Temperature: | 10° to 40° |
| Short Circuit Protection: | Shutdown |
Physical Characteristics:
Chassis/Rackmount Enclosure Support:
Warranty Information:
Ordering Information :
E-mail: sales@pcwnet.com
PCWMicrosystems, Inc.